Ozak GL A1

Power Requirements : 110/220 V. 60/50 Hz. AC (%±10) 24 V. DC at standby ~2W. max. ~65W.
Wing Features : Impact resistant 10 mm thick tempered glass (Opt. Polycarbon or Acrylic). Available in 550 mm or 900 mm standard lengths.
Body Features : Single piece 304-Grade (Opt. 316-Grade) satin finished and circular stainless steel body. Standard 20 mm thick natural granite (Star Galaxy Black) stone top lid for a decorative and aesthetical appearance.
Operation Temperature,
Humidity,IP Rating, MCBF
: -20°C to + 68°C (Opt. -50°C with heater unit), RH 95% non-condensing / IP 44 Indoor Model (For pipe wing versions IP 56 Option is avaliable.) / 1M Cycle
Control System : All inputs are opto-coupler protected. Compatible with all access control systems that provide dry contact or grounding outputs. Optional RS232/RS485/TCP IP control module is available.
Operation : Electronically controlled DC motor driven bi-directional system.
Emergency Mode : System allows free passage in emergency mode and in case of power failure.
Flow Rate : Wing Opening / Closing Time ~1,5 / – 2,5 sec.
Standard Features : Circular RGB LED direction and status indicator.
Optional Accessories
and Applications
: Remote control unit, interface unit for PC, RS485, RS232 and LAN, counter, audio-messaging system, floor mounting plate, separator, card reader pole. Exit Gate functionality to be used on Emergency Escape Routes as per EltVTR 1997-12 and DIN EN 60950-1:2011-01 (GL A1 FWZ)

Continue reading

Ozak 700 E

Power Requirements : 110/220 V. 60/50 Hz. AC (%±10) 24V. DC at standby ~4,4 W. max. ~12 W.
Arms : Ø40 mm x 2 mm 304-Grade stainless steel (Opt. 316 – Grade Stainless Steel).
Body Features : 1,5 mm 304-Grade (Opt. 316-Grade) stainless steel with brushed (Opt. Satin) surface.
Operation Temperature,
Humidity,IP Rating, MCBF
: -20°C to +68°C (Opt. -50°C with heater unit), RH 95% non-condensing / IP 54 Outdoor Model (Opt. IP 56) / 1M Cycles
Control System : All inputs are opto-coupler protected. Compatible with all access control systems that provide dry contact or grounding outputs. Optional RS232/RS485/TCP IP control module is available.
Operation : Manually operated bi-directional system (optional motorized) with dip switch selectable operational modes including controlled access on both sides, one side free (exit or entry) and other side controlled access and access restriction modes.
Emergency Mode : System allows free passage in emergency mode and in case of power failure.
Flow Rate : Capacity of Mechanism (Manual System): max. 97 passages/minute, Nominal: ~20 passages/minute
Capacity of Mechanism (Motorized System): max. 48 passages/minute, Nominal: ~16 passages/minute
Standard Features : Direction and status indicators
Optional Accessories
and Applications
: Remote control units, interface unit for PC, RS485, RS232 and LAN, counter, audio-messaging system, motor driven unit, automatic drop (retractable) arm, alarm sensor, heater positive unit, coin slot/intelligent coin system and coin box, card reader pole, pipe barrier (Separator), floor mounting plate, customised top covers to accommodate various accessories.

Continue reading

Ozak 500 E

Power Requirements : 110/220 V. 60/50 Hz. AC (%±10) 24 V. DC at standby ~4,4 W. max. ~12 W.
Arms : Ø40 mm x 2 mm 304-Grade stainless steel (Opt. 316 – Grade Stainless Steel).
Body Features : 1,5 mm 304-Grade (Opt. 316-Grade) stainless steel with brushed (Opt. Satin) surface.
Operation Temperature,
Humidity,IP Rating, MCBF
: -20°C to +68°C (Opt. -50°C with heater unit), RH 95% non-condensing / IP 54 Outdoor Model (Opt. IP 56) / 1M Cycles
Control System : All inputs are opto-coupler protected. Compatible with all access control systems that provide dry contact or grounding outputs. Optional RS232/RS485/TCP IP control module is available.
Operation : Manually operated bi-directional system (optional motorized) with dip switch selectable operational modes including controlled access on both sides, one side free (exit or entry) and other side controlled access and access restriction modes.
Emergency Mode : System allows free passage in emergency mode and in case of power failure.
Flow Rate : Capacity of Mechanism (Manual System): max. 97 passages/minute, Nominal: ~20 passages/minute
Capacity of Mechanism (Motorized System): max. 48 passages/minute, Nominal: ~16 passages/minute
Standard Features : Direction and status indicators
Optional Accessories
and Applications
: Remote control units, interface unit for PC, RS485, RS232 and LAN, counter, audio-messaging system, motor driven unit, automatic drop (retractable) arm, alarm sensor, heater positive unit, coin slot/intelligent coin system and coin box, card reader pole, pipe barrier (Separator), floor mounting plate, customised top covers to accommodate various accessories.

 

Continue reading